Basic Info.
Energy Efficiency Grade
Three
Work Environment
Common Heat Pump
Heat Source
Ground-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, CSA
Function
Air Condition, Floor Heating, Hot Water
Trademark
HVAC Trading, OEM
Specification
CCC, ISO9001, CE, ISO14001, SGS
Product Description
Product Name | Control Way | Main Feature | Function | Muted Boolean | Energy Saving | Energy Saving Level |
Heat Pump | Keying / Remote control | Central air conditioning, Floor heating and Hot water for living | Monitoring PM2.5, Temperature, Water and oxygen | YES | 50% | 1 Grade |
Sketch:
Ground source heat pump is a land of shallow energy by entering a small amount of high-grade energy (such as electricity) from low grade thermal energy to the high grade heat transfer.General in the air conditioning system, In Winter heat pump as heat source of heating and cooling in summer .That means in winter heat pump can get the energy from ground and raise the temperature of that energy in order to warm the room , in summer ,heat pump get the energy from room and release it to the ground.Ground source heat pump usually 1 kWh of energy consumption, users can get 4.4 kWh above the amount of heat or cold.
Feature:
1.Central air conditioning, floor heating and living hot water of the trinity,
Energy-saving effect more than 50%;.
2.High stability, central air conditioning the disadvantage is the weather hot or cold when most in need of cold quantity or heat efficiency declines, geothermal invarible around 16 ºC all the year round, slightly higher than the average temperature in the region of 1 to 2 ºC, make no matter heat pump in cooling or heating conditions are in high efficiency;
3.Green environmental protection, ground source heat pump of the pollutants discharge, compared with the air heat pump is equal to the reduced by more than 38%, compared with electric heating, equivalent to reduce more than 70%, real realize the energy conservation and emissions reduction, emissions to the environment and less energy, maintain the balance of ecological environment
4.No leaking gas, heating without burning process, to avoid the smoke exhaust pollution, no gas leaks, heating costs far less than the gas boiler heating, no combustion equipment, thus there is no explosion, fire, poisoning hazards;
5.No frost attenuation, air-cooled heat pump, freon air conditioning as long as the fan system, all have great relationship with the outdoor temperature, usually 5 ºC below zero in the outdoor environment, the host only 80% heat, low temperature have been unable to heating, ground source heat pump is the problem, any system of environment temperature were rated heat;
6.No save energy costs, runtime, COP can reach more than 4.5 and the input 1 KW, 4.5 KW available amount of cold, electrical heating means of energy efficiency for 3-4 times, and heat exchange does not need to defrost, reduce the energy consumption of frosting and defrosting, than conventional air source air conditioning energy saving more than 40%;
7.Super hot water, heat recovery technology used to super living hot water supply, higher efficiency, more plenty of hot water supply,
Hot water temperature can reach 55 to 60 ºC high temperature;
8.Pleasant and comfortable, no radiation, no noise, because of the ground source heat pump units for the changes in temperature is through hot and cold water after the fan coil (or floor tube, exchange of buried pipe wall), produced by the air conditioning and heating (or radiation) is much softer than the conventional air conditioning, and not easy to catch a cold, one of the best common central air conditioning need at least 67 decibels, and a host of platform source heat pump only 49 decibels.And computer room is placed within the room, so indoor to unmute.
Technical parameters:
The Host I |
Unit Type | EHM03/II | EHM05/II | EHM07/II | EHM10/II | EHM14/II | EHM18/II |
Refrigerating Capacity(KW) | 5-15 | 16-25 | 26-35 | 36-45 | 46-65 | 66-80 |
User side in and out of the water pipe diameter(mm) | DN32/DN32 | DN40/DN40 | DN40/DN40 | DN50/DN50 | DN50/DN50 | DN50/DN50 |
Water side in and out of the water pipe diameter(mm) | DN32/DN32 | DN40/DN40 | DN40/DN40 | DN50/DN50 | DN50/DN50 | DN50/DN50 |
Power Supply :380V/3ph/50HZ, |
Input Rated(KW) | 1.6 | 2.3 | 2.4 | 3.1 | 4.4 | 4.6 |
Size(L/W/H)(mm) | 875*710*750 | 875*710*750 | 875*710*750 | 875*710*750 | 875*710*750 | 875*710*750 |
Net Weight (Kg) | 110 | 110 | 110 | 120 | 120 | 188 |
Area(m2) | 0.62 | 0.62 | 0.62 | 0.62 | 0.62 | 0.62 |
Water tank(L) | 150L | 200L | 300L | 400L | 500L | 600L |
Buffer water tank (L) | 100L | 150L | 200L | 300L | 400L | 500L |
The Host II |
Unit Type | EHM25/II | EHM35/II | EHM40/II | EHM50/II | EHM60/II | EHM80/II |
Refrigerating Capacity(KW) | 81-115 | 116-160 | 161-240 | 241-300 | 301-360 | 370-460 |
User side in and out of the water pipe diameter(mm) | DN80/DN80 | DN80/DN80 | DN100/DN100 | DN100/DN100 | DN100/DN100 | DN125/DN125 |
Water side in and out of the water pipe diameter(mm) | DN80/DN80 | DN80/DN80 | DN100/DN100 | DN100/DN100 | DN100/DN100 | DN125/DN125 |
Power Supply :380V/3ph/50HZ, |
Input Rated(KW) | 8.2 | 8.4 | 11.2 | 11.4 | 15.2 | 22 |
Size(L/W/H)(mm) | 1130*792*1015 | 1130*792*1015 | 1350*900*1170 | 1350*900*1170 | 1350*900*1170 | 1950*1055*1600 |
Net Weight (Kg) | 208 | 232 | 312 | 328 | 41 | 570 |
Area(m2) | 0.89 | 0.89 | 1.22 | 1.22 | 1.22 | 2.06 |
The Host III |
Unit Type | EHM100/II | EHM120/II | EHM140/II | EHM160/II | EHM180/II | EHM200/II |
Refrigerating Capacity(KW) | 460-580 | 116-160 | 700-810 | 810-930 | 930-1050 | 1050-1160 |
User side in and out of the water pipe diameter(mm) | DN125/DN125 | DN150/DN150 | DN150/DN150 | DN200/DN200 | DN200/DN200 | DN200/DN200 |
Water side in and out of the water pipe diameter(mm) | DN125/DN125 | DN150/DN150 | DN150/DN150 | DN200/DN200 | DN200/DN200 | DN200/DN200 |
Main Power:380V/3ph/50HZ, |
Input Rated(KW) | 23 | 30 | 32 | 44 | 44.4 | 45 |
Size(L/W/H)(mm) | 1950*1055*1600 | 2300*1150*1700 | 2300*1150*1700 | 2400*1290*1910 | 2400*1290*1910 | 2400*1290*1910 |
Net Weight(Kg) | 570 | 575 | 605 | 610 | 610 | 610 |
Area(m2) | 2.06 | 2.65 | 2.65 | 3.1 | 3.1 | 3.1 |
Waste heat recycling host |
Unit Type | EHM03/II | EHM05/II | EHM07/II | EHM10/II | EHM14/II | EHM18/II |
Capacity(KW) | 5-15 | 16-25 | 26-35 | 36-45 | 46-65 | 66-80 |
User side in and out of the water pipe diameter(mm) | DN32/DN32 | DN40/DN40 | DN40/DN40 | DN50/DN50 | DN50/DN50 | DN50/DN50 |
Water side in and out of the water pipe diameter | DN32/DN32 | DN40/DN40 | DN40/DN40 | DN50/DN50 | DN50/DN50 | DN50/DN50 |
Power Supply:380V/3ph/50HZ,,Hot water recycle pump Power supply :220/50Hz |
Input Rated (KW) | 1.6 | 2.3 | 2.4 | 3.1 | 4.4 | 4.6 |
Size(L/W/H)(mm) | 875*710*750 | 875*710*750 | 875*710*750 | 875*710*750 | 875*710*750 | 875*710*750 |
Net Weight(Kg) | 110 | 110 | 110 | 120 | 120 | 188 |
Area(m2) | 0.62 | 0.62 | 0.62 | 0.62 | 0.62 | 0.62 |
Water tank Capacity (L) | 150L | 200L | 300L | 400L | 500L | 600L |
Buffer Water Tank Capacity(L) | 100L | 150L | 200L | 300L | 400L | 500L |
Address:
Room 1-8018, No. 789, Xiangcheng Avenue, Xiangcheng District, Suzhou, Jiangsu, China
Business Type:
Trading Company
Business Range:
Agriculture & Food, Apparel & Accessories, Bags, Cases & Boxes, Construction & Decoration, Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components, Light Industry & Daily Use, Manufacturing & Processing Machinery, Packaging & Printing
Management System Certification:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, IATF16949, ISO 14064
Company Introduction:
Suzhou HVAC Trading Co., Ltd established in 2004, located in Suzhou City near by Shanghai only 1 hour journey by car
We offer all kinds of solar water heater, low pressurized solar water heater (80L-300L), Compact pressurized solar water heater (80L-300L), split and pressurized solar water heater (80L-1000L)
Include neccessory accessories used on solar water heater such as silicion coil, tube support, bracket, assisstant tank, Heat pipe solar collector (Pipes 10-Pipes 36), Working station, Expansion Tank, Copper Connector, PE tube...Ect
We offer technology to install solar water heater for domestic and big solar project for school, hospital, hotel...We arrange engineer go aborad to install solar water heater until be finished well
Second we offer Ultrasonic Cutting Machine, Webbing Cutting Machine...For FIBC bag
We manufacture these machine and install them test them by ourself, we have already exported them to Vietnam, maylasia, Singapore, Indonesia, India...Neighbouring countries
We also can go aboard offer technology to install these machine until be finished well